AI Lighting Design — Vietnam

AI Lighting Design for Vietnam — TCVN 7114 Compliant

Momik automates lighting design in Revit. Fully TCVN 7114 compliant. Weeks of work in minutes.

500×Faster workflow
100%TCVN 7114 compliant
5 minPer project
0Clashes
Book a Demo →

Lighting Standard in Vietnam

Standard TCVN 7114
Full Title TCVN 7114:2008 — Lighting of work places
Standards Body STAMEQ (Directorate for Standards)
Capital Hanoi
Locale vi-VN

Why Momik for Vietnam?

500× Faster

What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.

TCVN 7114 Built In

Every design meets TCVN 7114 requirements automatically. No manual norm-checking needed.

Native Revit

Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.

Zero Clashes

AI-powered clash detection ensures every fixture placement is structurally valid from the start.

TCVN 7114 Illuminance Requirements

Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under TCVN 7114.

Room / Task Type Illuminance (Em) Uniformity (Uo) Glare (UGR) Colour (Ra)
Open-plan office500 lx≥ 0.60≤ 19≥ 80
Meeting / conference room500 lx≥ 0.60≤ 19≥ 80
Reception / lobby300 lx≥ 0.40≤ 22≥ 80
Corridor / circulation100 lx≥ 0.40≤ 28≥ 40
Staircase150 lx≥ 0.40≥ 40
Toilet / WC200 lx≥ 0.40≤ 25≥ 80
Warehouse (general)200 lx≥ 0.40≤ 25≥ 60
Manufacturing (med. prec.)500 lx≥ 0.60≤ 19≥ 80

Compliance & Enforcement

In Vietnam, TCVN 7114 sets the national standard for workplace and building illumination. Ministry of Construction (Bộ Xây dựng) / MOLISA oversees technical compliance under QCVN 22:2016/BYT. Building permit applications for commercial and industrial projects require lighting design calculations. Periodic workplace inspections verify ongoing compliance with minimum illuminance requirements.

Enforcement Body
Ministry of Construction (Bộ Xây dựng) / MOLISA
Legal Basis
QCVN 22:2016/BYT
Standard
TCVN 7114

Key Sectors

Primary industries where TCVN 7114 compliance is most frequently required in Vietnam.

Industrial & Manufacturing Commercial Offices Healthcare Education

Frequently Asked Questions

Yes. In Vietnam, TCVN 7114 is adopted as the national standard for workplace illumination. Ministry of Construction (Bộ Xây dựng) / MOLISA oversees compliance under QCVN 22:2016/BYT. Building permits for commercial and industrial developments require lighting calculations demonstrating conformity. Workplace safety inspections include verification of minimum illuminance levels.

Buildings that fail to meet TCVN 7114 requirements can receive improvement notices from Ministry of Construction (Bộ Xây dựng) / MOLISA. In severe cases, occupancy permits may be revoked until lighting is retrofitted to meet minimum levels. Employers also face occupational health liability if inadequate lighting contributes to worker injuries or health issues.

Momik reads your Revit model room by room, automatically applies TCVN 7114 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.