Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under TIS 1955.
| Room / Task Type | Illuminance (Em) | Uniformity (Uo) | Glare (UGR) | Colour (Ra) |
|---|---|---|---|---|
| Open-plan office | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Meeting / conference room | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Reception / lobby | 300 lx | ≥ 0.40 | ≤ 22 | ≥ 80 |
| Corridor / circulation | 100 lx | ≥ 0.40 | ≤ 28 | ≥ 40 |
| Staircase | 150 lx | ≥ 0.40 | — | ≥ 40 |
| Toilet / WC | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 80 |
| Warehouse (general) | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 60 |
| Manufacturing (med. prec.) | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
In Thailand, TIS 1955 sets the national standard for workplace and building illumination. Department of Industrial Works (DIW) / MOL oversees technical compliance under Ministerial Regulation on Labour Protection. Building permit applications for commercial and industrial projects require lighting design calculations. Periodic workplace inspections verify ongoing compliance with minimum illuminance requirements.
Primary industries where TIS 1955 compliance is most frequently required in Thailand.
Yes. In Thailand, TIS 1955 is adopted as the national standard for workplace illumination. Department of Industrial Works (DIW) / MOL oversees compliance under Ministerial Regulation on Labour Protection. Building permits for commercial and industrial developments require lighting calculations demonstrating conformity. Workplace safety inspections include verification of minimum illuminance levels.
Buildings that fail to meet TIS 1955 requirements can receive improvement notices from Department of Industrial Works (DIW) / MOL. In severe cases, occupancy permits may be revoked until lighting is retrofitted to meet minimum levels. Employers also face occupational health liability if inadequate lighting contributes to worker injuries or health issues.
Momik reads your Revit model room by room, automatically applies TIS 1955 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.