Momik automates lighting design in Revit. Fully SANS 10114-1 compliant. Weeks of work in minutes.
What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.
Every design meets SANS 10114-1 requirements automatically. No manual norm-checking needed.
Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.
AI-powered clash detection ensures every fixture placement is structurally valid from the start.
Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under SANS 10114-1.
| Room / Task Type | Illuminance (Em) | Uniformity (Uo) | Glare (UGR) | Colour (Ra) |
|---|---|---|---|---|
| Open-plan office | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Meeting / conference room | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Reception / lobby | 300 lx | ≥ 0.40 | ≤ 22 | ≥ 80 |
| Corridor / circulation | 100 lx | ≥ 0.40 | ≤ 28 | ≥ 40 |
| Staircase | 150 lx | ≥ 0.40 | — | ≥ 40 |
| Toilet / WC | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 80 |
| Warehouse (general) | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 60 |
| Manufacturing (med. prec.) | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
In South Africa, SANS 10114-1 provides the technical framework for workplace lighting design. Department of Employment and Labour / SABS monitors compliance through workplace safety inspections under Occupational Health and Safety Act 85/1993 / SANS 10114. Commercial building permits increasingly require lighting design documentation, particularly for projects involving international financing or sustainability certification.
Primary industries where SANS 10114-1 compliance is most frequently required in South Africa.
Yes. In South Africa, SANS 10114-1 is adopted as the technical standard for workplace lighting. Department of Employment and Labour / SABS references this standard in its enforcement of Occupational Health and Safety Act 85/1993 / SANS 10114. Commercial building permit requirements are increasingly requiring lighting design documentation that demonstrates compliance with the standard.
Department of Employment and Labour / SABS oversees workplace safety compliance, including lighting requirements, under Occupational Health and Safety Act 85/1993 / SANS 10114. Building control authorities require lighting design submissions for commercial and public building permits. For internationally financed or certified projects, third-party verification against SANS 10114-1 is standard practice.
Momik reads your Revit model room by room, automatically applies SANS 10114-1 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.