AI Lighting Design — Slovenia

AI Lighting Design for Slovenia — SIST EN 12464-1 Compliant

Momik automates lighting design in Revit. Fully SIST EN 12464-1 compliant. Weeks of work in minutes.

500×Faster workflow
100%SIST EN 12464-1 compliant
5 minPer project
0Clashes
Book a Demo →

Lighting Standard in Slovenia

Standard SIST EN 12464-1
Full Title SIST EN 12464-1 — Lighting of work places
Standards Body SIST (Slovenški inštitut za standardizacijo)
Capital Ljubljana
Locale sl-SI

Why Momik for Slovenia?

500× Faster

What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.

SIST EN 12464-1 Built In

Every design meets SIST EN 12464-1 requirements automatically. No manual norm-checking needed.

Native Revit

Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.

Zero Clashes

AI-powered clash detection ensures every fixture placement is structurally valid from the start.

SIST EN 12464-1 Illuminance Requirements

Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under SIST EN 12464-1.

Room / Task Type Illuminance (Em) Uniformity (Uo) Glare (UGR) Colour (Ra)
Open-plan office500 lx≥ 0.60≤ 19≥ 80
Meeting / conference room500 lx≥ 0.60≤ 19≥ 80
Reception / lobby300 lx≥ 0.40≤ 22≥ 80
Corridor / circulation100 lx≥ 0.40≤ 28≥ 40
Staircase150 lx≥ 0.40≥ 40
Toilet / WC200 lx≥ 0.40≤ 25≥ 80
Warehouse (general)200 lx≥ 0.40≤ 25≥ 60
Manufacturing (med. prec.)500 lx≥ 0.60≤ 19≥ 80

Compliance & Enforcement

In Slovenia, SIST EN 12464-1 is incorporated into national workplace safety legislation through Pravilnik o zahtevah za zagotavljanje varnosti in zdravja. Labour Inspectorate (IRSD) is responsible for overseeing compliance through workplace and building inspections. For commercial, industrial, and public buildings, lighting design documentation demonstrating conformity with SIST EN 12464-1 must be submitted as part of the building permit application. Non-compliance can result in improvement notices and, in serious cases, suspension of occupancy permits.

Enforcement Body
Labour Inspectorate (IRSD)
Legal Basis
Pravilnik o zahtevah za zagotavljanje varnosti in zdravja
Standard
SIST EN 12464-1

Key Sectors

Primary industries where SIST EN 12464-1 compliance is most frequently required in Slovenia.

Commercial Offices Industrial & Manufacturing Healthcare Education

Frequently Asked Questions

Yes. In Slovenia, SIST EN 12464-1 is referenced in Pravilnik o zahtevah za zagotavljanje varnosti in zdravja as the applicable technical standard for workplace lighting. All commercial, industrial, and public buildings must comply. Building inspectors from Labour Inspectorate (IRSD) verify compliance during construction reviews and occupancy inspections. Failure to meet requirements can result in improvement notices or suspension of the building use permit.

Buildings that fail to meet SIST EN 12464-1 illuminance requirements can receive enforcement notices from Labour Inspectorate (IRSD). Persistent non-compliance may result in fines, revocation of occupancy permits, or mandatory retrofitting. Beyond regulatory consequences, inadequate lighting increases occupational health risks — including reduced productivity, eye strain, and accident risk — creating liability exposure for employers.

Momik reads your Revit model room by room, automatically applies SIST EN 12464-1 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.