Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under MES 006.
| Room / Task Type | Illuminance (Em) | Uniformity (Uo) | Glare (UGR) | Colour (Ra) |
|---|---|---|---|---|
| Open-plan office | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Meeting / conference room | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Reception / lobby | 300 lx | ≥ 0.40 | ≤ 22 | ≥ 80 |
| Corridor / circulation | 100 lx | ≥ 0.40 | ≤ 28 | ≥ 40 |
| Staircase | 150 lx | ≥ 0.40 | — | ≥ 40 |
| Toilet / WC | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 80 |
| Warehouse (general) | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 60 |
| Manufacturing (med. prec.) | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
In Myanmar, MES 006 sets the national standard for workplace and building illumination. Ministry of Construction / MOALI oversees technical compliance under Myanmar National Building Code. Building permit applications for commercial and industrial projects require lighting design calculations. Periodic workplace inspections verify ongoing compliance with minimum illuminance requirements.
Primary industries where MES 006 compliance is most frequently required in Myanmar.
Yes. In Myanmar, MES 006 is adopted as the national standard for workplace illumination. Ministry of Construction / MOALI oversees compliance under Myanmar National Building Code. Building permits for commercial and industrial developments require lighting calculations demonstrating conformity. Workplace safety inspections include verification of minimum illuminance levels.
Buildings that fail to meet MES 006 requirements can receive improvement notices from Ministry of Construction / MOALI. In severe cases, occupancy permits may be revoked until lighting is retrofitted to meet minimum levels. Employers also face occupational health liability if inadequate lighting contributes to worker injuries or health issues.
Momik reads your Revit model room by room, automatically applies MES 006 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.