AI Lighting Design — Mongolia

AI Lighting Design for Mongolia — MNS 5765 Compliant

Momik automates lighting design in Revit. Fully MNS 5765 compliant. Weeks of work in minutes.

500×Faster workflow
100%MNS 5765 compliant
5 minPer project
0Clashes
Book a Demo →

Lighting Standard in Mongolia

Standard MNS 5765
Full Title MNS 5765 — Interior lighting of buildings
Standards Body MASM (Mongolian Agency for Standardization)
Capital Ulaanbaatar
Locale mn-MN

Why Momik for Mongolia?

500× Faster

What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.

MNS 5765 Built In

Every design meets MNS 5765 requirements automatically. No manual norm-checking needed.

Native Revit

Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.

Zero Clashes

AI-powered clash detection ensures every fixture placement is structurally valid from the start.

MNS 5765 Illuminance Requirements

Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under MNS 5765.

Room / Task Type Illuminance (Em) Uniformity (Uo) Glare (UGR) Colour (Ra)
Open-plan office500 lx≥ 0.60≤ 19≥ 80
Meeting / conference room500 lx≥ 0.60≤ 19≥ 80
Reception / lobby300 lx≥ 0.40≤ 22≥ 80
Corridor / circulation100 lx≥ 0.40≤ 28≥ 40
Staircase150 lx≥ 0.40≥ 40
Toilet / WC200 lx≥ 0.40≤ 25≥ 80
Warehouse (general)200 lx≥ 0.40≤ 25≥ 60
Manufacturing (med. prec.)500 lx≥ 0.60≤ 19≥ 80

Compliance & Enforcement

In Mongolia, MNS 5765 sets the national standard for workplace and building illumination. National Construction Authority of Mongolia oversees technical compliance under MNS Building Lighting Standard. Building permit applications for commercial and industrial projects require lighting design calculations. Periodic workplace inspections verify ongoing compliance with minimum illuminance requirements.

Enforcement Body
National Construction Authority of Mongolia
Legal Basis
MNS Building Lighting Standard
Standard
MNS 5765

Key Sectors

Primary industries where MNS 5765 compliance is most frequently required in Mongolia.

Industrial & Manufacturing Commercial Offices Healthcare Education

Frequently Asked Questions

Yes. In Mongolia, MNS 5765 is adopted as the national standard for workplace illumination. National Construction Authority of Mongolia oversees compliance under MNS Building Lighting Standard. Building permits for commercial and industrial developments require lighting calculations demonstrating conformity. Workplace safety inspections include verification of minimum illuminance levels.

Buildings that fail to meet MNS 5765 requirements can receive improvement notices from National Construction Authority of Mongolia. In severe cases, occupancy permits may be revoked until lighting is retrofitted to meet minimum levels. Employers also face occupational health liability if inadequate lighting contributes to worker injuries or health issues.

Momik reads your Revit model room by room, automatically applies MNS 5765 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.