AI Lighting Design — Japan

AI Lighting Design for Japan — JIS Z 9110 Compliant

Momik automates lighting design in Revit. Fully JIS Z 9110 compliant. Weeks of work in minutes.

500×Faster workflow
100%JIS Z 9110 compliant
5 minPer project
0Clashes
Book a Demo →

Lighting Standard in Japan

Standard JIS Z 9110
Full Title JIS Z 9110:2010 — General rules of recommended lighting levels
Standards Body JISC (Japanese Industrial Standards Committee)
Capital Tokyo
Locale ja-JP

Why Momik for Japan?

500× Faster

What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.

JIS Z 9110 Built In

Every design meets JIS Z 9110 requirements automatically. No manual norm-checking needed.

Native Revit

Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.

Zero Clashes

AI-powered clash detection ensures every fixture placement is structurally valid from the start.

JIS Z 9110 Illuminance Requirements

Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under JIS Z 9110.

Room / Task Type Illuminance (Em) Uniformity (Uo) Glare (UGR) Colour (Ra)
Office (standard task)750 lx≥ 0.70≤ 19≥ 80
Meeting / conference room500 lx≥ 0.60≤ 22≥ 80
Reception / lobby300 lx≥ 0.40≤ 22≥ 80
Corridor / circulation200 lx≥ 0.40≥ 60
Staircase150 lx≥ 0.40≥ 60
Toilet / WC200 lx≥ 0.40≤ 25≥ 80
Warehouse (general)200 lx≥ 0.40≥ 60
Manufacturing (med. prec.)1000 lx≥ 0.60≤ 19≥ 80

Compliance & Enforcement

In Japan, JIS Z 9110 sets the national standard for workplace and building illumination. Ministry of Land, Infrastructure, Transport and Tourism (MLIT) oversees technical compliance under JIS Z 9110:2010. Building permit applications for commercial and industrial projects require lighting design calculations. Periodic workplace inspections verify ongoing compliance with minimum illuminance requirements.

Enforcement Body
Ministry of Land, Infrastructure, Transport and Tourism (MLIT)
Legal Basis
JIS Z 9110:2010
Standard
JIS Z 9110

Key Sectors

Primary industries where JIS Z 9110 compliance is most frequently required in Japan.

Industrial & Manufacturing Commercial Offices Healthcare Education

Frequently Asked Questions

Yes. In Japan, JIS Z 9110 is adopted as the national standard for workplace illumination. Ministry of Land, Infrastructure, Transport and Tourism (MLIT) oversees compliance under JIS Z 9110:2010. Building permits for commercial and industrial developments require lighting calculations demonstrating conformity. Workplace safety inspections include verification of minimum illuminance levels.

Buildings that fail to meet JIS Z 9110 requirements can receive improvement notices from Ministry of Land, Infrastructure, Transport and Tourism (MLIT). In severe cases, occupancy permits may be revoked until lighting is retrofitted to meet minimum levels. Employers also face occupational health liability if inadequate lighting contributes to worker injuries or health issues.

Momik reads your Revit model room by room, automatically applies JIS Z 9110 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.