AI Lighting Design — Ivory Coast

AI Lighting Design for Ivory Coast — NI ISO 8995 Compliant

Momik automates lighting design in Revit. Fully NI ISO 8995 compliant. Weeks of work in minutes.

500×Faster workflow
100%NI ISO 8995 compliant
5 minPer project
0Clashes
Book a Demo →

Lighting Standard in Ivory Coast

Standard NI ISO 8995
Full Title NI ISO 8995 — Lighting of indoor work places
Standards Body CODINORM (Côte d’Ivoire Normalisation)
Capital Yamoussoukro
Locale fr-CI

Why Momik for Ivory Coast?

500× Faster

What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.

NI ISO 8995 Built In

Every design meets NI ISO 8995 requirements automatically. No manual norm-checking needed.

Native Revit

Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.

Zero Clashes

AI-powered clash detection ensures every fixture placement is structurally valid from the start.

NI ISO 8995 Illuminance Requirements

Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under NI ISO 8995.

Room / Task Type Illuminance (Em) Uniformity (Uo) Glare (UGR) Colour (Ra)
Open-plan office500 lx≥ 0.60≤ 19≥ 80
Meeting / conference room500 lx≥ 0.60≤ 19≥ 80
Reception / lobby300 lx≥ 0.40≤ 22≥ 80
Corridor / circulation100 lx≥ 0.40≤ 28≥ 40
Staircase150 lx≥ 0.40≥ 40
Toilet / WC200 lx≥ 0.40≤ 25≥ 80
Warehouse (general)200 lx≥ 0.40≤ 25≥ 60
Manufacturing (med. prec.)500 lx≥ 0.60≤ 19≥ 80

Compliance & Enforcement

In Ivory Coast, NI ISO 8995 provides the technical framework for workplace lighting design. Inspection du Travail / BNETD monitors compliance through workplace safety inspections under Code du Travail de Côte d'Ivoire. Commercial building permits increasingly require lighting design documentation, particularly for projects involving international financing or sustainability certification.

Enforcement Body
Inspection du Travail / BNETD
Legal Basis
Code du Travail de Côte d'Ivoire
Standard
NI ISO 8995

Key Sectors

Primary industries where NI ISO 8995 compliance is most frequently required in Ivory Coast.

Commercial Buildings Healthcare Education Public Infrastructure

Frequently Asked Questions

Yes. In Ivory Coast, NI ISO 8995 is adopted as the technical standard for workplace lighting. Inspection du Travail / BNETD references this standard in its enforcement of Code du Travail de Côte d'Ivoire. Commercial building permit requirements are increasingly requiring lighting design documentation that demonstrates compliance with the standard.

Inspection du Travail / BNETD oversees workplace safety compliance, including lighting requirements, under Code du Travail de Côte d'Ivoire. Building control authorities require lighting design submissions for commercial and public building permits. For internationally financed or certified projects, third-party verification against NI ISO 8995 is standard practice.

Momik reads your Revit model room by room, automatically applies NI ISO 8995 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.